Suitable for safety functions
No
Voltage type of supply voltage
DC
Supporting protocol for LON
No
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Supporting protocol for TCP/IP
Yes
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
Yes
Supporting protocol for KNX
No
Supporting protocol for MODBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for other bus systems
Yes
Suitable for welding control
No
Suitable for pressure control
No
Function electronic positioning available
No
Suitable for incremental data detection
Yes
Suitable for detection absolute value
No
Flux controller possible
No
Suitable for flux measurement
No
Suitable for path controller
No
Suitable for cam controller
No
Suitable for flying saw
Yes
Suitable for multi-axis control
Yes
Single-axis controller possible
Yes
Suitable for multi-axis positioning
Yes
Single-axis positioning possible
Yes
Rail mounting possible
Yes
Explosion safety category for gas
None
Explosion safety category for dust
None
Fieldbus connection over separate bus coupler possible
Yes
SIL according to IEC 61508
0
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Degree of protection (IP)
Other
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Category according to EN 954-1
1
Number of HW-interfaces PROFINET
0
Number of HW-interfaces Wireless
0
Front build in possible
No
Rack-assembly possible
Yes
Wall mounting/direct mounting
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Function block automatic reset
Yes
Function block contactless working protection installation
No
Function block operating mode selection
Yes
Function block emergency stop
No
Function block restart blockage
Yes
Function block acces control
Yes
Function block affirm pushbutton
Yes
Function block 2-hand switching
No
Contactor control function block
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Suitable for temperature control
No